WIRELESS NURSE CALL SYSTEM FOR SMALL TO MEDIUM SIZE CARE HOMES AND HOSPITALS |
|
The Central Monitor will receive and display signals from all patient call devices; washroom pull cord transmitters, bed head call point transmitters, bed and chair occupancy sensors, wristband transmitters and DoorWatcher anti-wander systems. When activated by a patient call, the CMU-02 produces an audible tone alarm with volume adjustment. The display will indicate the type of transmitter, toilet, bed head etc, with backlit display. The monitor also displays with audible alarm the condition of the system, radio interference problems, low battery warnings for all devices, missing or broken items. Any number of CMU-02’s can be used in a system. One per floor or area is recommended. |
|
|
|
The CMU-02 is powered by 12V DC power adaptor with battery backup provided by 4 x D cell batteries. Dimensions: H 205 mm x W 145mm x D 42mm. |
|
|
|
Pull Cord Transmitter: (WCP-02 For bathroom, toilets and lounge areas. 85mm x 85mm x 10mm Powered by sealed in Lithium battery with a service life of five years. Reassurance LED lights to confirm operation to user. Fitted with 3M red pull cord with pull triangles. RF power 4mW max, narrow band digital transmission for maximum range and reliability. Range 25M. 100% waterproof making it suitable for bath-side or shower room fixing. |
|
|
|
Wireless Reset Button: (WRE-02) Required to reset WCP-02 pull cord transmitter. 85mm x 85mm x 10mm. Powered by sealed in Lithium battery with a service life of five years. Reassurance LED lights to confirm operation to user. RF power 4mW max, range 25M. |
|
|
|
|
|
|
|
Where a repeater panel is required in another area of the building the ILB-03 can be used as a general alarm for a group of rooms or patients, saving the requirement of a nurse call display for that area. Powered by 4 x D cell batteries. |
|
|
|
The PAG-03 is a lightweight pager with call display that also speaks call point identification numbers independently of the Central Monitor. The pager has a volume button for high or low volume. When a call point is pushed, or bed or chair sensor triggers the BTXV-NCT transmitter, the pager will announce the room or bed number. Note, the pager does not allow for zone location, IE: 00 for ground floor it will only announce the two digit room or bed numbers. Powered by 2 x AA batteries. Dimensions: W 80mm H 58mm D 18mm. Weight including batteries 116g. Simple low cost paging solution. |
|
|

|
CMU-02 |

|
WRE-02 |
|
WCP-02 |