3 Melbourne House, Corby Gate Business Park
Priors Haw Road, Corby, Northants, NN17 5JG. UK

Tel: 01536 264 869  Email
Home Page.
Epilepsy.
Health Care Products.
Security -  Paging.
Deaf & HOH.
Company & Info.
View Cart
Fire Centurion FC-CH
Designed To Acoustically Detect
Hotel Room Fire Alarm Sounder

VAT Exemption is available in the UK for this item. Click VAT exemption to read the procedure and download the appropriate form. When we receive the completed form a refund of the VAT amount will be sent to you either electronically of by post.

Wire-Free Smoke Alarm System For Deaf & Hard Of Hearing People FC-CH2D

The Fire Centurion, first introduced to the UK market in 1989 has been engineered to provide a deaf or hard of hearing person with a reliable means of waking up during a fire in the home. A smoke detector containing a transmitter signals a bedside alarm when smoke is detected. The system is supplied with 2 x radio controlled smoke detectors.

 

The bedside alarm has a flashing xenon strobe and powerful vibrating pillow shaker that is switched on when an alarm signal is received by either smoke detector. Clearly labelled LED’s indicate the status of the system:

 

Fire Alert

Power supply status

Backup battery status

Alarm clock input

Sounder detection*

 

The FC-CH2S has circuitry that detects fire alarm claxons, such as those used in hotels. Built in sensors detect operation of a commercial fire alarm sounder. After the sound pattern has been validated as a fire alarm sounder, the attached vibrating pad and xenon flashing light operate until the unit is reset by pressing the alarm cancel button.

 

The FC-CH2S alarm has a relay output socket and an auxiliary power output that can be used to operate radio paging equipment, telephone auto diallers or connection to other emergency alarms. A socket is also provided for use with a Shake Awake vibrating alarm clock. Simple plug in and use setup.

 

General Specifications

 

Bedside alarm FC-CH Bedside alarm

 

Dimensions 180 x 115 x 50mm. Powered by 12V AC power adaptor. 120 Hour battery back-up. Radio frequency 868. 25 MHz. Xenon high intensity strobe light. Vibrating pillow with 2 Metre lead. 9-12V 180mA. External output socket for connection of additional strobe light and radio paging interfaces. 3 Year product guarantee. System test button. Auxiliary power output, 12 V DC. Relay output, N/O closing on alarm. Electronic power control. Radio pager available. Battery backup 96 hours.

 

Smoke detector FC-CHD

 

Battery operated (9V Lithium) Ionisation Type. Dimensions 138 x 125 x 45mm. Ceiling fixing kit supplied. R&TTE certified. EMC certified. Production quality monitored. Transmitter frequency 868.92 MHz. Transmitter range 100 Metres. Conforms to BS 5446:III:2005

 

 

ORDER CODE FC-CH2S PRICE £138.00 + VAT (£162.15) Price includes bedside alarm, 2 x smoke detectors with 10 year Lithium batteries. UK delivery £9.25.

 

Fire Centurion FC-CH2D

£138.00

Item:

Price:

Add Fire Centurion FC-CH2D to cart

Manufactured in the UK